[Spécifications]:8 AO(tension)
[Interfaces de communication]:RJ45, RS485
[Tension de fonctionnement]:DC 9 à 36 V
[Montage]:Rail DIN + trous de positionnement
[Dimensions]:110 * 25 * 100 mm
[Poids]:125 ± 5 g
[Introduction]:Ces modules d'extension d'E/S distribuées hautes performances sont extensibles et nécessitent l'utilisation des châssis d'E/S distribuées Modbus, Profinet, CANopen et EtherCAT de la série M31. Le boîtier est recouvert d'un revêtement conforme, offrant une protection contre les moisissures, l'humidité et les embruns salins.

| M31-GXXXB0008-U Port and Button Description: | ||
| silkscreen | name | illustrate |
| AO1 | AO1 Analog voltage output (positive) | AO1 is the analog output (positive) interface, used in conjunction with GND1. |
| GND1 | AO1 Analog voltage output (negative terminal) | AO1 Analog Output (Negative) Interface |
| AO2 | AO2 Analog voltage output (positive) | AO2 is the analog output (positive) interface, used in conjunction with GND2. |
| GND2 | AO2 Analog voltage output (negative terminal) | AO2 analog output (negative) interface |
| AO3 | AO3 Analog Voltage Output (Positive) | AO3 is the analog output (positive) interface, used in conjunction with GND3. |
| GND3 | AO3 Analog Voltage Output (Negative) | AO3 Analog Output (Negative) Interface |
| AO4 | AO4 Analog voltage output (positive) | AO4 is the analog output (positive) interface, used in conjunction with GND4. |
| GND4 | AO4 Analog voltage output (negative terminal) | AO4 Analog Output (Negative) Interface |
| AO5 | AO5 Analog Voltage Output (Positive) | AO5 is the analog output (positive) interface, used in conjunction with GND5. |
| GND5 | AO5 Analog voltage output (negative terminal) | AO5 Analog Output (Negative) Interface |
| AO6 | AO6 Analog voltage output (positive) | AO6 is the analog output (positive) interface, used in conjunction with GND6. |
| GND6 | AO6 Analog voltage output (negative terminal) | AO6 Analog Output (Negative) Interface |
| AO7 | AO7 Analog Voltage Output (Positive) | AO7 is the analog output (positive) interface, used in conjunction with GND7. |
| GND7 | AO7 Analog Voltage Output (Negative) | AO7 Analog Output (Negative) Interface |
| AO8 | AO8 Analog Voltage Output (Positive) | AO8 is the analog output (positive) interface, used in conjunction with GND8. |
| GND8 | AO8 Analog Voltage Output (Negative) | AO8 Analog Output (Negative) Interface |
| NC | Empty terminal (Not Care) | No actual circuit connection function |
| NC | Empty terminal (Not Care) | No actual circuit connection function |
| NC | Empty terminal (Not Care) | No actual circuit connection function |
| M31-GXXXA0008-U Indicator Light Description: | ||
| silkscreen | name | illustrate |
| RUN | Power indicator light | Red LED light; On: System power supply is normal; Off: System power supply is abnormal. |
| BUS | Device bus status indicator | Yellow LED light; On: Internal bus operating normally; Off: Internal bus operating completely abnormally; Flashing: Internal bus operation may be abnormal. |
| STA | Bus communication indicator | Blue LED; flashing: indicates data exchange between the host and the expansion module; off: indicates no data exchange between the host and the expansion module. |
| AO1 | AO1 Output Indicator | Green LED light; On: Normal output reaches 1% or more of the range; Off: No effective output. |
| AO2 | AO2 Output Indicator | Green LED light; On: Normal output reaches 1% or more of the range; Off: No effective output. |
| AO3 | AO3 Output Indicator | Green LED light; On: Normal output reaches 1% or more of the range; Off: No effective output. |
| AO4 | AO4 Output Indicator | Green LED light; On: Normal output reaches 1% or more of the range; Off: No effective output. |
| AO5 | AO5 Output Indicator Light | Green LED light; On: Normal output reaches 1% or more of the range; Off: No effective output. |
| AO6 | AO6 Output Indicator | Green LED light; On: Normal output reaches 1% or more of the range; Off: No effective output. |
| AO7 | AO7 Output Indicator | Green LED light; On: Normal output reaches 1% or more of the range; Off: No effective output. |
| AO8 | AO8 Output Indicator | Green LED light; On: Normal output reaches 1% or more of the range; Off: No effective output. |