[Spécifications]:16AI entrées analogiques
[Interface de communication]:RJ45, RS485
[Tension de fonctionnement]:DC 9~36V
[Montage]:Trou de positionnement, montage sur rail DIN
[Dimensions]:110 × 25 × 100 mm
[Poids]:125 ± 5 g
[Introduction]:Ces modules d'extension d'E/S distribuées hautes performances sont extensibles et compatibles avec les hôtes d'E/S distribuées Modbus, Profinet, CANopen et EtherCAT de la série M31. Le boîtier est recouvert d'un revêtement conforme offrant une protection contre les moisissures, l'humidité et les embruns salins.

| M31-GXBXX0A00-U Port and Button Description: | ||
| Silk screen | Name | Description |
| AI1 | AI1 analog voltage input | AI1 analog input interface for use with COMA |
| FW2 | AI2 analog voltage input | AI2 analog input interface for use with COMA |
| FW3 | AI3 analog voltage input | AI3 analog input interface for use with COMA |
| FW4 | AI4 analog voltage input | AI4 analog input interface for use with COMA |
| FW5 | AI5 analog voltage input | AI5 analog input interface for use with COMA |
| FW6 | AI6 analog voltage input | AI6 analog input interface for use with COMA |
| FW7 | AI7 analog voltage input | AI7 analog input interface for use with COMA |
| FW8 | AI8 analog voltage input | AI8 analog input interface for use with COMA |
| COMA | AI analog input is public | AI1-AI8 共用 COMA 公共端 |
| FW9 | AI9 analog voltage input | AI9 analog input interface for use with COMB |
| FW10 | AI10 analog voltage input | AI10 analog input interface for use with COMB |
| FW11 | AI11 analog voltage input | AI11 analog input interface for use with COMB |
| FW12 | AI12 analog voltage input | AI12 analog input interface for use with COMB |
| FW13 | AI13 analog voltage input | AI13 analog input interface for use with COMB |
| FW14 | AI14 analog voltage input | AI14 analog input interface for use with COMB |
| FW15 | AI15 analog voltage input | AI15 analog input interface for use with COMB |
| FW16 | AI16 analog voltage input | AI16 analog input interface for use with COMB |
| COMB | AI analog input is public | AI9-AI16 share the COMB public end |
| NC | Not Care | No actual circuit connection function |
| M31-GXAXX0A00-U indicator description: | ||
| Silk screen | Name | Description |
| RUN | Power indicator | red LED light; Bright: The system power supply is normal; Extinguished: The system power supply is abnormal |
| BUS | Device bus status indicator | yellow LED light; Light: The internal bus of the equipment is running normally; Extinguished: The internal bus operation of the equipment is completely abnormal; Flickering: There may be abnormalities in the operation of the internal bus of the device |
| STA | Bus communication indicator | Blue LED lights; Flashing: indicates that there is data interaction between the host and the extension module; Permanently extinguished: Indicates that there is no data interaction between the host and the extension module |
| AI1 | AI1 input indicator | Green LED lights; Bright : normal input reaches 1% and above the range; Extinguished: Invalid access; Fast flashing: 10% out of range |
| FW2 | AI2 input indicator | Green LED lights; Bright : normal input reaches 1% and above the range; Extinguished: Invalid access; Fast flashing: 10% out of range |
| FW3 | AI3 input indicator | Green LED lights; Bright : normal input reaches 1% and above the range; Extinguished: Invalid access; Fast flashing: 10% out of range |
| FW4 | AI4 input indicator | Green LED lights; Bright : normal input reaches 1% and above the range; Extinguished: Invalid access; Fast flashing: 10% out of range |
| FW5 | AI5 input indicator | Green LED lights; Bright : normal input reaches 1% and above the range; Extinguished: Invalid access; Fast flashing: 10% out of range |
| FW6 | AI6 input indicator | Green LED lights; Bright : normal input reaches 1% and above the range; Extinguished: Invalid access; Fast flashing: 10% out of range |
| FW7 | AI7 input indicator | Green LED lights; Bright : normal input reaches 1% and above the range; Extinguished: Invalid access; Fast flashing: 10% out of range |
| FW8 | AI8 input indicator | Green LED lights; Bright : normal input reaches 1% and above the range; Extinguished: Invalid access; Fast flashing: 10% out of range |
| FW9 | AI9 input indicator | Green LED lights; Bright : normal input reaches 1% and above the range; Extinguished: Invalid access; Fast flashing: 10% out of range |
| FW10 | AI10 input indicator | Green LED lights; Bright : normal input reaches 1% and above the range; Extinguished: Invalid access; Fast flashing: 10% out of range |
| FW11 | AI11 input indicator | Green LED lights; Bright : normal input reaches 1% and above the range; Extinguished: Invalid access; Fast flashing: 10% out of range |
| FW12 | AI12 input indicator | Green LED lights; Bright : normal input reaches 1% and above the range; Extinguished: Invalid access; Fast flashing: 10% out of range |
| FW13 | AI13 input indicator | Green LED lights; Bright : normal input reaches 1% and above the range; Extinguished: Invalid access; Fast flashing: 10% out of range |
| FW14 | AI14 input indicator | Green LED lights; Bright : normal input reaches 1% and above the range; Extinguished: Invalid access; Fast flashing: 10% out of range |
| FW15 | AI15 input indicator | Green LED lights; Bright : normal input reaches 1% and above the range; Extinguished: Invalid access; Fast flashing: 10% out of range |
| FW16 | AI16 input indicator | Green LED lights; Bright : normal input reaches 1% and above the range; Extinguished: Invalid access; Fast flashing: 10% out of range |